Rabu, 17 Mei 2017

VLAN TRUNKING



1.SWITCH
Switch > enable
Switch # conf t
Switch(config)#vlan database
Switch(config-vlan)#vlan 10 name ruang10
Switch(config-vlan)#vlan 20 name ruang20
Switch(config-vlan)#exit
Switch # config terminal
Switch(config)#interfaces fa0/1
Switch(config-if)#switchport mode access
Switch(config-if)#switchport access vlan 10
Switch(config)#interfaces fa0/2
Switch(config-if)#switchport mode access
Switch(config-if)#switchport access vlan 10
Switch(config)#interfaces fa0/3
Switch(config-if)#switchport mode access
Switch(config-if)#switchport access vlan 20
Switch(config)#interfaces fa0/4
Switch(config-if)#switchport mode access
Switch(config-if)#switchport access vlan 20



2.switch
Switch > enable
Switch # config terminal
Switch(config)#interfaces fa0/5
Switch(config-if)#switchport mode access
Switch(config-if)#switchport access vlan 10
Switch(config)#interfaces fa0/6
Switch(config-if)#switchport mode access
Switch(config-if)#switchport access vlan 20
Switch(config)#interfaces fa0/24
Switch(config-if)#switchport mode trunk
Switch(config-if)#ex

SOAL SUBNETTING

SOAL SUBNETTING

DIKETAHUI : 10.10.10.29
DITANYA :

1.IP MAXIMAL
2.NETMAKS
3.NETWORK
4.BROADCAST
5.HOST

KELAS C
/24=256
/25=128
/26=64
/27=32
/28=16
/29=8
/30=4

1. IP MAXIMAL = 8
2. NETMAKS = 255.255.255.(256-8)
                           255.255.255.248
3. NETWORK = 10.10.10.0
4. BROADCAST = 10.10.10.7
5. HOST = 10.10.10.1 -  10.10.10.6